8 resultados para TRANSCRANIAL DOPPLER ULTRASONOGRAPHY

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to study dynamic changes of ovaries in rhesus macaques stimulated by gonadotropins to identify an indicator for predicting ovarian response to stimulation. Twenty-one cycling monkeys were given 36 IU/d recombinant human follicle-stimulat

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Undoped, Zn-doped and Te-doped GaSb with different concentrations were investigated by positron lifetime spectroscopy (PAS) and the Doppler broadening technique. Detection sensitivity of the latter technique was improved by using a second Ge-detector for the coincident detection of the second annihilation photon. PAS measurement indicated that there were vacancies in these samples. By combining the Doppler broadening measurements, the native acceptor defects in GaSb were identified to be predominantly Ga vacancy (V-Ga) related defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present the results of coincidence Doppler broadening (CDB) measurements and positron lifetime spectroscopy (PLS) on the semiconductor material GaSb. Gallium vacancy with positron lifetime of about 283 ps (V-Ga, (283 ps)) was identified in as-grown sample by CDB technique and PAS technique. For electron irradiated samples with dosages of 10(17) cm(-2) and 10(18) cm(-2), the PAS showed almost the same defectrelated positron lifetime of about 285 ps. CDB experiments indicated that defects in irradiated samples were related to Ga vacancies. (c) 2006 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Undoped, Zn-doped and Te-doped GaSb with different concentrations were investigated by positron lifetime spectroscopy (PAS) and the Doppler broadening technique. Detection sensitivity of the latter technique was improved by using a second Ge-detector for the coincident detection of the second annihilation photon. PAS measurement indicated that there were vacancies in these samples. By combining the Doppler broadening measurements, the native acceptor defects in GaSb were identified to be predominantly Ga vacancy (V-Ga) related defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the study is to investigate the suitability of using Pulse-coherent Acoustic Doppler Profiler (PCADP) to estimate suspended sediment concentration (SSC). The acoustic backscatter intensity was corrected for spreading and absorption loss, then calibrated with OBS and finally converted to SSC. The results show that there is a good correlation between SSC and backscatter intensity with R value of 0.74. The mean relative error is 22.4%. Then the time span of little particle size variation was also analyzed to exclude the influence of size variation. The correlation coefficient increased to 0.81 and the error decreased to 18.9%. Our results suggest that the PCADP can meet the requirement of other professional instruments to estimate SSC with the errors between 20% and 50%, and can satisfy the need of dynamics study of suspended particles.